User Manual
TMCM-3351 CANopen® Firmware Manual • Firmware Version V3.22 | Document Revision V1.01 • 2019-FEB-14
61 / 145
Object Description
Index Name Object Type Data Type
209D
h
Smart Energy Filter Enable Variable UNSIGNED8
Table 155: Object Description (209D
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0/1 0
Table 156: Entry Description (209D
h
)
4.2.51 Object 209E
h
: StallGuard2 Threshold
This signed value controls the StallGuard2 threshold level for stall output and sets the optimum measure-
ment range for readout. A lower value gives a higher sensitivity. Zero is the starting value. A higher value
makes StallGuard2 less sensitive and requires more torque to indicate a stall.
Object Description
Index Name Object Type Data Type
209E
h
StallGuard2 Threshold Variable SIGNED8
Table 157: Object Description (209E
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no -63. . . 63 0
Table 158: Entry Description (209E
h
)
4.2.52 Object 20A1
h
: Short Protection Disable
This object is used to enable or to disable the short to ground protection. Normally there is no need to
change this. Use the default value.
Possible values are:
• 0 – Short to GND protection enabled
• 1 – Short to GND protection disabled
Object Description
Index Name Object Type Data Type
20A1
h
Short Protection Disable Variable UNSIGNED8
Table 159: Object Description (20A1
h
)
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com