User Manual

TMCM-3314, TMCM-3315 Hardware Manual (V1.00 / 2018-APR-30) 9
Copyright © 2016-2018, TRINAMIC Motion Control GmbH & Co. KG
Connector and mating connector overview:
Label
Mating connector type
RS485
Molex MicroFit™,
Housing: 43645-0300
Contacts: 43030-0007
CAN
e.g. Standard CAT 5 / CAT 5e
cables may be used
USB
Standard Micro-USB
Inputs
Molex MicroFit™,
Housing: 43025-1000
Contacts: 43030-0007
Outputs
Molex MicroFit™,
Housing: 43025-0800
Contacts: 43030-0007
Table 5.1 TMCM-3314 interface brick: connectors and mating connectors
5.1.1 RS485 connector
There are two RS485 connectors on the board with the same pin assignment pins directly connected to each
other. The second connector may be used for attaching a bus termination resistor to the RS485 bus (there is no
termination resistor on-board) or for further distribution of the RS485 bus signals to other RS485 communication
nodes while maintaining a proper bus structure.
A three pin Molex MicroFitconnector (Molex part no. 436500315) is used for RS485 connection. Mating connector
housing e.g. Molex 43645-0300, contacts Molex 43030-0007. Please note that there are alternative options available
from Molex for both, housing and contacts.
1
3
Pin
Label
Direction
Description
1
GND
Power
Supply and signal ground
2
RS485+
Bi-directional
RS485 interface, diff. signal (non-inverting)
3
RS485-
Bi-directional
RS485 interface, diff signal (inverting)
Table 5.1: Interface Brick: RS485 connector
5.1.2 CAN connector
There are two CAN connectors on the board with the same pin assignment pins directly connected to each
other. The second one may be used for attaching a bus termination resistor to the RS485 bus (there is no
termination resistor on-board) or for further distribution of the CAN bus signals to other CAN nodes while
maintaining a proper bus structure.
A standard RJ45 plug connector is used for CAN communication. Standard CAT cables (e.g. CAT 5, non-crossing)
might be used for connection. Pin assignment of the RJ45 is based on the CiA 303-1 recommendation.
1
8
Pin
Label
Direction
Description
1
CAN_H
Bi-Directional
CAN interface, diff signal (non-inverting)
2
CAN_L
Bi-directional
CAN interface, diff signal (inverting)
3
GND
Power
Supply and signal ground
4
n.c.
5
n.c.
6
n.c.
7
n.c.
8
n.c.
Table 5.2 Interface Brick: CAN connector