User Manual
TMCM-3314, TMCM-3315 Hardware Manual (V1.00 / 2018-APR-30) 9
Copyright © 2016-2018, TRINAMIC Motion Control GmbH & Co. KG
Connector and mating connector overview:
Label
Connector type
Mating connector type
RS485
Molex MicroFit™, 436500315
1x4 pin header, 3mm pitch
Molex MicroFit™,
Housing: 43645-0300
Contacts: 43030-0007
CAN
RJ45 plug connector
e.g. Standard CAT 5 / CAT 5e
cables may be used
USB
Micro-USB connector, type B
(USB device interface)
Standard Micro-USB
Inputs
Molex MicroFit™, 430451012
2x5 pin header, 3mm pitch
Molex MicroFit™,
Housing: 43025-1000
Contacts: 43030-0007
Outputs
Molex MicroFit™, 430450812
2x4 pin header, 3mm pitch
Molex MicroFit™,
Housing: 43025-0800
Contacts: 43030-0007
Table 5.1 TMCM-3314 interface brick: connectors and mating connectors
5.1.1 RS485 connector
There are two RS485 connectors on the board with the same pin assignment – pins directly connected to each
other. The second connector may be used for attaching a bus termination resistor to the RS485 bus (there is no
termination resistor on-board) or for further distribution of the RS485 bus signals to other RS485 communication
nodes while maintaining a proper bus structure.
A three pin Molex MicroFit™ connector (Molex part no. 436500315) is used for RS485 connection. Mating connector
housing e.g. Molex 43645-0300, contacts Molex 43030-0007. Please note that there are alternative options available
from Molex for both, housing and contacts.
1
3
Pin
Label
Direction
Description
1
GND
Power
Supply and signal ground
2
RS485+
Bi-directional
RS485 interface, diff. signal (non-inverting)
3
RS485-
Bi-directional
RS485 interface, diff signal (inverting)
Table 5.1: Interface Brick: RS485 connector
5.1.2 CAN connector
There are two CAN connectors on the board with the same pin assignment – pins directly connected to each
other. The second one may be used for attaching a bus termination resistor to the RS485 bus (there is no
termination resistor on-board) or for further distribution of the CAN bus signals to other CAN nodes while
maintaining a proper bus structure.
A standard RJ45 plug connector is used for CAN communication. Standard CAT cables (e.g. CAT 5, non-crossing)
might be used for connection. Pin assignment of the RJ45 is based on the CiA 303-1 recommendation.
1
8
Pin
Label
Direction
Description
1
CAN_H
Bi-Directional
CAN interface, diff signal (non-inverting)
2
CAN_L
Bi-directional
CAN interface, diff signal (inverting)
3
GND
Power
Supply and signal ground
4
n.c.
5
n.c.
6
n.c.
7
n.c.
8
n.c.
Table 5.2 Interface Brick: CAN connector