User Manual
TMCM-3314, TMCM-3315 Hardware Manual (V1.00 / 2018-APR-30) 25
Copyright © 2016-2018, TRINAMIC Motion Control GmbH & Co. KG
7.3 TMCM-3315 Interface Brick
With the TMCM-3315, there are five LEDs available. Two LEDs are connected to the processor and three to the
EtherCAT™ slave controller (ESC). In addition, one LED (ERROR) is connected to both, the microcontroller and the
ESC.
Figure 7.3: LEDs on TMCM-3315 interface brick
LED
Description
EtherCAT™ LINK IN
Signal LINK IN, connected to ESC
EtherCAT™ LINK OUT
Signal LINK OUT, connected to ESC
EtherCAT RUN
Indicating status of EtherCAT state machine, connected to ESC
ERROR
Connected to microcontroller and ESC – indicating Error
LED (green)
Connected to microcontroller – flashing slowly during normal operation
8 Reset to Factory Default
For reset to factory default values please follow instructions below:
1. Switch OFF power supply.
2. Short two pads of programming connector pad-array (see figure 8.1).
3. Switch ON power supply (on-board LED should be flashing fast / faster than during normal operation).
4. Switch OFF power supply.
5. Remove short circuit.
Figure 8.1 Reset to factory defaults (bottom view of pcb - interface brick end)