Datasheet

TMCM-3314 TMCL
Firmware Manual Firmware Version V1.09 | Document Revision V1.07 2017-DEC-01
78 / 109
Number Axis Parameter Description Range [Units] Access
174 stallGuard2
threshold
This signed value controls stallGuard2 threshold
level for stall output and sets the optimum mea-
surement range for readout. A lower value gives
a higher sensitivity. Zero is the starting value.
A higher value makes stallGuard2 less sensitive
and requires more torque to indicate a stall.
-64. . . +63 RW
180 smartEnergy
actual current
This status value provides the actual motor cur-
rent setting as controlled by coolStep. The value
goes up to the CS value and down to the portion
of CS as specied by SEIMIN.
Actual motor current scaling factor:
0. . . 31: 1/32, 2/32, . . . 32/32
0. . . 31 R
181 Stop on stall
Below this speed motor will not be stopped.
Above this speed motor will stop in case stall-
Guard2 load value reaches zero.
0. . .
2147483647
[pps]
RW
182 smartEnergy
threshold
speed
Above this speed coolStep becomes enabled. 0. . .
2147483647
[pps]
RW
184 Random TO
mode
0 - Chopper o time is xed
1 - Chopper o time is random
0/1 RW
185 Chopper syn-
chronization
This parameter allows synchronization of the
chopper for both phases of a two phase motor
in order to avoid the occurrence of a beat, espe-
cially at low velocities.
0: chopper sync function chopSync o
1. . . 15: chopper synchronization
0. . . 15 RW
186
PWM threshold
speed
The stealthChop feature will be switched o
when the actual velocity is higher than this value.
It will be switched on when the actual velocity is
below this value (and parameter #187 is greater
than zero).
0. . .
2147483647
[pps]
RW
187 PWM gradient
Velocity dependent gradient for PWM amplitude
(stealthChop). Setting this value to 0 turns o
stealthChop.
0. . . 15 RW
188 PWM
amplitude
Maximum PWM amplitude when switching to
stealthChop mode. Do not set too low. Values
above 64 recommended.
0. . . 255 RW
189 PWM scale
Actual PWM amplitude scaler (255=maximum
voltage). In voltage mode PWM, this value allows
to detect a motor stall.
0. . . 255 R
190 PWM mode
Status of stealthChop voltage PWM mode (de-
pending on velocity thresholds).
0 - stealthChop disabled
1 - stealthChop enabled
0/1 R
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com