Number Axis Parameter Description Range [Units] Access
167 Chopper o
time (TO)
The o time setting controls the minimum
chopper frequency. An o time within the range
of 5µs to 20µs will t.
O time setting for constant t O chopper:
N
CLK
= 12 + 32 tOF F (Minimum is 64 clocks)
Setting this parameter to zero completely dis-
ables all driver transistors and the motor can
free-wheel.
0. . . 15 RW
168 smartEnergy
current
minimum
(SEIMIN)
Sets the lower motor current limit for coolStep
operation by scaling the maximum current (see
axis parameter 6) value.
Minimum motor current:
0 -
1
2
of CS
1 -
1
4
of CS
0/1 RW
169 smartEnergy
current down
step
Sets the number of stallGuard2 readings above
the upper threshold necessary for each current
decrement of the motor current. Number of
stallGuard2 measurements per decrement:
Scaling: 0. . . 3: 32, 8, 2, 1
0: slow decrement
3: fast decrement
0. . . 3 RW
170 smartEnergy
hysteresis
Sets the distance between the lower and the
upper threshold for stallGuard2 reading. Above
the upper threshold the motor current becomes
decreased. Hysteresis: ([AP 172] + 1) 32
Upper stallGuard threshold: ([
AP
172]+[
AP
170]+
1) 32
0. . . 15 RW
171 smart Energy
current up step
Sets the current increment step. The current
becomes incremented for each measured stall-
Guard2 value below the lower threshold see
smartEnergy hysteresis start). Current incre-
ment step size:
Scaling: 0. . . 3: 1, 2, 4, 8
0: slow increment
3: fast increment / fast reaction to rising load
0. . . 3 RW
172 smart Energy
hysteresis start
The lower threshold for the stallGuard2 value
(see smart Energy current up step).
0. . . 15 RW
173 stallGuard2
lter enable
Enables the stallGuard2 lter for more precision
of the measurement. If set, reduces the mea-
surement frequency to one measurement per
four fullsteps. In most cases it is expedient to
set the ltered mode before using coolStep. Use
the standard mode for step loss detection.
0 - standard mode
1 - ltered mode
0/1 RW