User Manual

TMCM-3313 CoE Firmware Manual Firmware Version V1.01 | Document Revision V1.02 2016-NOV-29
60 / 110
Value Denition
Value Denition
1 Slow down on slow down ramp and transit into switch on disabled
2 Slow down on quick stop ramp and transit into switch on disabled
5 Slow down on slow down ramp and stay in quick stop active)
6 Slow down on quick stop ramp and stay in quick stop active
Table 162: Value Description (605A
h
)
Object Description
Index Name Object Type Data Type
605A
h
Quick stop option code Variable SIGNED16
Table 163: Object Description (605A
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 1/2/5/6 2
Table 164: Entry Description (605A
h
)
5.1.2 Object 605B
h
: Shutdown option code
This object indicates what action is performed if there is a transition from operation enabled state to ready
to switch on state. The shutdown option code always has the value 0 as only this is supported.
Value Denition
Value Denition
0 Disable drive function (switch o the power stage)
Table 165: Value Description (605B
h
)
Object Description
Index Name Object Type Data Type
605B
h
Shutdown option code Variable UNSIGNED16
Table 166: Object Description (605B
h
)
©2016 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com
Read entire documentation.