User Manual

TMCM-3313 CoE Firmware Manual Firmware Version V1.01 | Document Revision V1.02 2016-NOV-29
51 / 110
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 15 0
Table 127: Entry Description (209C
h
)
4.2.48 Object 209D
h
: Smart Energy Filter Enable
This object is used to set the stallGuard2 lter for more precision of the measurement. It reduces the
measurement frequency to one measurement per four fullsteps if set.
In most cases it is expedient to set the ltered mode when using coolStep. Use the standard mode for
step loss detection.
Possible values are:
0 standard mode
1 ltered mode
Object Description
Index Name Object Type Data Type
209D
h
Smart Energy Filter Enable Variable UNSIGNED8
Table 128: Object Description (209D
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0/1 0
Table 129: Entry Description (209D
h
)
4.2.49 Object 209E
h
: stallGuard2 Threshold
This signed value controls the stallGuard2 threshold level for stall output and sets the optimum measure-
ment range for readout. A lower value gives a higher sensitivity. Zero is the starting value. A higher value
makes stallGuard2 less sensitive and requires more torque to indicate a stall.
Object Description
Index Name Object Type Data Type
209E
h
stallGuard2 Threshold Variable SIGNED8
Table 130: Object Description (209E
h
)
©2016 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com
Read entire documentation.