4.2.42 Object 2097
h
: Chopper Off Time
The off time setting controls the minimum chopper frequency. Under normal circumstances, an off time
within the range of 5
µ
s to 20
µ
s is used. Off time setting for constant t
OFF
chopper:
N
CLK
= 12 + 32
∗ t
OF F
.
Minimum is 64 clocks.
Setting this parameter to zero completely disables all driver transistors and so lets the motor free-wheel.
Object Description
Index Name Object Type Data Type
2097
h
Chopper Off Time Variable UNSIGNED8
Table 116: Object Description (2097
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0 / 2. . . 15 5
Table 117: Entry Description (2097
h
)
4.2.43 Object 2098
h
: Smart Energy Current Minimum
This object provides the setting of the lower motor current limit for coolStep operation by scaling the CS
value.
Possible values are:
• 0 – 1/2 of maximum motor current setting (section 4.2.4)
• 1 – 1/4 of maximum motor current setting (section 4.2.4)
Object Description
Index Name Object Type Data Type
2098
h
Smart Energy Current Minimum Variable UNSIGNED8
Table 118: Object Description (2098
h
)