User Manual

TMCM-3313 CoE Firmware Manual Firmware Version V1.01 | Document Revision V1.02 2016-NOV-29
47 / 110
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 3 0
Table 111: Entry Description (2094
h
)
4.2.40 Object 2095
h
: Chopper Hysteresis End
This object provides the setting of the hysteresis end value after a number of decrements. The decrement
interval time is controlled by object 2094
h
(section 4.2.39).
Possible values are:
-3. . . -1 negative hysteresis end setting
0 zero hysteresis end setting
1. . . 12 positive hysteresis end setting
Object Description
Index Name Object Type Data Type
2095
h
Chopper Hysteresis End Variable SIGNED8
Table 112: Object Description (2095
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no -3. . . 12 0
Table 113: Entry Description (2095
h
)
4.2.41 Object 2096
h
: Chopper Hysteresis Start
This object provides the hysteresis start setting. Please notice that this value is an oset to the hysteresis
end value.
Object Description
Index Name Object Type Data Type
2096
h
Chopper Hysteresis Start Variable UNSIGNED8
Table 114: Object Description (2096
h
)
©2016 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com
Read entire documentation.