User Manual
TMCM-3230 Hardware Manual • Hardware Version V1.30 | Document Revision V1.20 • 2019-MAR-01
16 / 22
7 Operational Ratings and Characteristics
7.1 Absolute Maximum Ratings
Parameter Min Max Unit
DC Power supply voltage for operation 9 28.5 V
+5V DC input (optional) 4.8 5.2 V
Motor coil current / sine wave peak 1.4 A
Continuous motor current (RMS) 1 A
Working / environmental temperature -30
*)
+40
**)
° C
Table 5: Absolute Maximum Ratings
*)
limited by test equipment. Operation down to -40
°
C can be expected. Test included cold start at this tempera-
ture.
**)
constant air flow or heat sink (e.g. mounted to the backside of the pcb (Attention: please make sure to isolate
heatsink from pcb)) may be required. All components are specified for operation up-to at least +85° C
NOTICE
Stresses above those listed under "Absolute Maximum Ratings" may cause perma-
nent damage to the device. This is a stress rating only and functional operation
of the device at those or any other conditions above those indicated in the op-
eration listings of this specification is not implied. Exposure to maximum rating
conditions for extended periods may affect device reliability.
7.2 Electrical Characteristics (Ambient Temperature 25° C)
Parameter Symbol Min Typ Max Unit
DC Power supply voltage for operation VDD 9 12..24 28 V
Motor coil current / sine wave
peak
(chop-
per regulated, adjustable in software)
I
COIL peak
0 1.4 A
Continuous motor current (RMS) I
COIL RMS
0 1.0 A
Power supply current I
DD
I
COIL
1.4
∗
I
COIL
A
Table 6: Electrical Characteristics
7.3 I/O Ratings (Ambient Temperature 25° C)
Parameter Symbol Min Typ Max Unit
Input voltage for general purpose inputs V
IN
0 0..5 5.5 V
Output voltage for general purpose outputs
V
OUT
0 0..5 5.5 V
Table 7: I/O Ratings
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.