Digital Outputs in Bank 2
Port Command Range
OUT0 SIO 0, 2, <value> 0/1
OUT1 SIO 1, 2, <value> 0/1
OUT2 SIO 2, 2, <value> 0/1
OUT3 SIO 3, 2, <value> 0/1
OUT4 SIO 4, 2, <value> 0/1
OUT5 SIO 5, 2, <value> 0/1
OUT6 SIO 6, 2, <value> 0/1
OUT7 SIO 7, 2, <value> 0/1
Special case: SIO 255, 2, <x> can be used to change all general purpose digital output lines simulaneously.
The value <x> will then be interpreted as a bit vector where each bit represents one of the digital outputs.
The value <x> can also be -1. In this case, the value will be taken from the accumulator register. The
following program can be used to copy the states of the input lines to the output lines:
1
Loop:
GIO 255, 0
3
SIO 255, 2, -1
JA Loop