User Manual
TMCM-3230 CANopen
®
Firmware Manual • Firmware Version V3.21 | Document Revision V1.05 • 2018-JAN-10
68 / 118
The motor will not run when the operating mode is set to 0. It will be stopped when the motor is running
in one of the supported operating modes and the operating mode is then switched to 0.
Object Description
Index Name Object Type Data Type
6061
h
Modes of operation display Variable SIGNED8
Table 197: Object Description (6061
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw refer to CiA-402 0/1/3/6 0
Table 198: Entry Description (6061
h
)
5.1.8 Object 60FD
h
: Digital Inputs
This object contains the states of the digital inputs of the module. Starting from bit 0, every bit reflects the
state of one digital input. The number of valid bits depends on the number of digital inputs on the module
used.
Object Description
Index Name Object Type Data Type
60FD
h
Digital inputs Variable UNSIGNED32
Table 199: Object Description (60FD
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw mappable UNSIGNED32 0
Table 200: Entry Description (60FD
h
)
5.1.9 Object 6502
h
: Supported Drive Modes
This object provides information on the supported drive modes. A bit that is set means that the mode is
supported, a bit that is not set means that the mode is not supported by the drive.