User Manual

TMCM-3230 CANopen
®
Firmware Manual Firmware Version V3.21 | Document Revision V1.05 2018-JAN-10
57 / 118
Object Description
Index Name Object Type Data Type
2700
h
TMCL Direct Communication Variable UNSIGNED32
Table 155: Object Description (2700
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 656b616d
h
0
Table 156: Entry Description (2700)
h
4.2.52 Object 2701
h
: Manufacturer Specic Mode
Writing the make signature to this object turns on the manufacturer specic mode. The manufacturer
specic mode can be turned o again by writing the kill signature to this object. The manufacturer specic
mode has the following features:
PDOs do not need to be disabled and re-enabled when the PDO mapping is to be changed.
The RTR bit in the COB-ID of PDO denitions is ignored.
read: 0 = manufacturer specic mode is inactive
1 = manufacturer specic mode is active
write: 656b616d
h
= make signature
6c6c696b
h
= kill signature
Object Description
Index Name Object Type Data Type
2701
h
Manufacturer Specic Mode Variable UNSIGNED32
Table 157: Object Description (2701
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no see above 0
Table 158: Entry Description (2701)
h
4.2.53 Object 2702
h
: Device Digital Inputs
Bits 23. . . 16 of this object reect the states of the general purpose inputs of the module. The number of
available inputs depends on the module type.
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com