User Manual

TMCM-3230 CANopen
®
Firmware Manual Firmware Version V3.21 | Document Revision V1.05 2018-JAN-10
53 / 118
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0/1 0
Table 137: Entry Description (20B8
h
)
4.2.43 Object 20B9
h
: Power Down Ramp
The value set by this object controls the number of clock cycles for motor power down after a motion as
soon as the motor has stopped and the setting time (set by object 2089
h
, please see section 4.2.14) has
expired. The smooth transition avoids a motor jerk upon power down.
0=instant power down.
15=longest possible power down ramp.
Object Description
Index Name Object Type Data Type
20B9
h
Power Down Ramp Variable UNSIGNED8
Table 138: Object Description (20B9
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 15 7
Table 139: Entry Description (20B9
h
)
4.2.44 Object 2100
h
: Home Oset Display
This object shows the home oset. The value is given in microsteps.
Object Description
Index Name Object Type Data Type
2100
h
Home Oset Display Variable SIGNED32
Table 140: Object Description (2100
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 ro no -2147483648. . . 2147483647 0
Table 141: Entry Description (2100
h
)
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com