User Manual
TMCM-3212, TMCM-3213 Hardware Manual (V0.95 / 2017-MAR-01) 24
Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG
7 On Board LEDs
There are a number of LEDs on-board indicating status.
7.1 Power supply brick
With the TMCM-3212 and TMCM-3213 three LEDs are available on the power supply brick part.
+5V auxilliary supply
+5V supply
+12V supply
Figure 7.1: LEDs on power supply brick
LED
Description
+12V supply
+12V available from on-board DC/DC converter for supply of the pre-driver circuit
+5V supply
+5V available from on-board DC/DC converter for supply of on-board digital circuit
+5V auxiliary supply
+5V auxiliary supply available (can be switched on/off in software). +5V_OUT on
REF/HOME and ENCODER connector.
7.2 TMCM-3212 Interface Brick
With the TMCM-3212 there are two LEDs (one green and one red) available. Both are connected to the on-board
microcontroller and function is firmware dependent. With TMCL firmware the green LED is flashing slowly during
operation. During firmware updates both LEDs are switched on.
LED (green)
LED (red)
Figure 7.2: LEDs on TMCM-3212 interface brick