User Manual

TMCM-3212 CANopen
®
Firmware Manual Firmware Version V3.20 | Document Revision V1.03 2017-JUN-09
85 / 119
Trinamic Specic Bits
Bit Name Denition
14 Motor activity 0: Motor stands still.
1: Motor rotates.
15 Direction of rotation This bit shows the direction of rotation.
Table 258: Trinamic Specic Bits
Operation Mode specic Bits in pv Mode
Bit Name Denition
10 Target reached Indicates that the target speed has been reached.
12 Speed Not supported.
13 Max. slippage error Not supported.
Table 259: Operation Mode specic Bits in pv Mode
State Coding
Status word FSA state
xxxx xxxx x0xx 0000
h
Not ready to switch on
xxxx xxxx x1xx 0000
h
Switch on disabled
xxxx xxxx x01x 0001
h
Ready to switch on
xxxx xxxx x01x 0011
h
Switched on
xxxx xxxx x01x 0111
h
Operation enabled
xxxx xxxx x00x 0111
h
Quick stop active
xxxx xxxx x0xx 1111
h
Fault reaction active
xxxx xxxx x0xx 1000
h
Fault
Table 260: State Coding
Object Description
Index Name Object Type Data Type
6041
h
Controlword Variable UNSIGNED16
Table 261: Object Description (6041
h
in pv Mode)
©2017 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany