5.4 Bank 3
Bank 3 contains interrupt parameters. Some interrupts need configuration (e.g. the timer interval of
a timer interrupt). This can be done using the SGP commands with parameter bank 3 (SGP <type>, 3,
<value>).
The priority of an interrupt depends on its number. Interrupts with a lower number have
a higher priority.
Table 18 shows all interrupt parameters that can be set. Please see table 15 for an explanation of the
parameter access types.
Interrupt Parameters in Bank 3
Number Global Parameter Description Range [Units] Access
0 Timer 0 period
(ms)
Time between two interrupts
0. . . 4294967295
[ms]
RW
1 Timer 1 period
(ms)
Time between two interrupts
0. . . 4294967295
[ms]
RW
2 Timer 2 period
(ms)
Time between two interrupts
0. . . 4294967295
[ms]
RW
27 Stop left 0 trigger
transition
0=off, 1=low-high, 2=high-low, 3=both 0. . . 3 RW
28
Stop right 0 trigger
transition
0=off, 1=low-high, 2=high-low, 3=both 0. . . 3 RW
39 Input 0 trigger
transition
0=off, 1=low-high, 2=high-low, 3=both 0. . . 3 RW
40 Input 1 trigger
transition
0=off, 1=low-high, 2=high-low, 3=both 0. . . 3 RW
41 Input 2 trigger
transition
0=off, 1=low-high, 2=high-low, 3=both 0. . . 3 RW
Table 18: Interrupt Parameters in Bank 3