User Manual
TMCM-1276 TMCL
™
Firmware Manual • Firmware Version V1.13 | Document Revision V1.01 • 2019-MAR-20
79 / 100
All Global Parameters of the TMCM-1276 Module in Bank 0
Number Global Parameter Description Range [Units] Access
69 CAN bit rate
2 20kBit/s
3 50kBit/s
4 100kBit/s
5 125kBit/s
6 250kBit/s
7 500kBit/s
8 1000kBit/s (Default)
2. . . 8 RWA
70 CAN reply ID
The CAN ID for replies from the board (de-
fault: 2).
0. . . 2047 RWA
71 CAN ID
The module (target) address for CAN (de-
fault: 1).
0. . . 2047 RWA
77 Auto start mode
0 - Do not start TMCL application after
power up (default).
1 - Start TMCL application automatically af-
ter power up.
0/1 RWA
81 TMCL code
protection
Protect a TMCL program against disassem-
bling or overwriting.
0 - no protection
1 - protection against disassembling
2 - protection against overwriting
3 - protection against disassembling and
overwriting
When switching off the protection
against disassembling (changing this
parameter from 1 or 3 to 0 or 2, the
program will be erased first!
0/1/2/3 RWA
82 CAN heartbeat
Heartbeat for CAN interface. If this time
limit is up and no further command is re-
ceived the motor will be stopped. Setting
this parameter to 0 (default) turns off the
CAN heartbeat function.
0. . . 65535 [ms] RWA
83 CAN secondary
address
Second CAN ID for the module. Switched
off when set to zero.
0. . . 2047 RWA
84 Coordinate
storage
0 - coordinates are stored in RAM only (but
can be copied explicitly between RAM and
EEPROM)
1 - coordinates are always also stored in the
EEPROM
0/1 RWA
85 Do not restore
user variables
Determines if TMCL user variables are to be
restored from the EEPROM automatically on
startup.
0 - user variables are restored (default)
1 - user variables are not restored
0/1 RWA