User Manual

TMCM-1276 TMCL
Firmware Manual Firmware Version V1.13 | Document Revision V1.01 2019-MAR-20
72 / 100
Number Axis Parameter Description Range [Units] Access
140 Microstep
resolution
Microstep resolutions per full step:
0 fullstep
1 halfstep
2 4 microsteps
3 8 microsteps
4 16 microsteps
5 32 microsteps
6 64 microsteps
7 128 microsteps
8 256 microsteps
0..8 RW
162 Chopper blank
time
Selects the comparator blank time. This time
needs to safely cover the switching event and
the duration of the ringing on the sense resistor.
Normally leave at the default value.
0..3 RW
163 Constant TO
mode
Selection of the chopper mode:
0 spread cycle
1 classic constant o time
0/1 RW
164 Disable fast
decay
comperator
See parameter 163. For classic const. o time
setting this parameter to 1 will disable current
comparator usage for termination of fast decay
cycle.
0/1 RW
165 Chopper
hysteresis end /
fast decay time
See parameter 163. For spread cycle chopper
mode this parameter will set / return the hys-
teresis end setting (hysteresis end value after a
number of decrements). For classic const. o
time chopper mode this parameter will set /
return the fast decay time.
0. . . 15 RW
166 Chopper
hysteresis start
/ sine wave
oset
See parameter 163. For spread cycle chopper
mode this parameter will set / return the Hys-
teresis start setting (please note that this value is
an oset to the hysteresis end value). For clas-
sic const. o time chopper mode this parameter
will set / return the sine wave oset.
0. . . 8 RW
167 Chopper o
time (TO)
The o time setting controls the minimum
chopper frequency. An o time within the range
of 5µs to 20µs will t.
O time setting for constant t O chopper:
N
CLK
= 12 + 32 tOF F (Minimum is 64 clocks)
Setting this parameter to zero completely dis-
ables all driver transistors and the motor can
free-wheel.
0. . . 15 RW
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com