User Manual
TMCM-1276 TMCL
™
Firmware Manual • Firmware Version V1.13 | Document Revision V1.01 • 2019-MAR-20
38 / 100
Binary Form of CALC MUL, -5000
Field Value
Target address 01
h
Instruction number 13
h
Type 02
h
Motor/Bank 00
h
Value (Byte 3) FF
h
Value (Byte 2) FF
h
Value (Byte 1) EC
h
Value (Byte 0) 78
h
Checksum 78
h
Reply (Status=no error, value=-5000:
Field Value
Host address 02
h
Target address 01
h
Status 64
h
Instruction 13
h
Value (Byte 3) FF
h
Value (Byte 2) FF
h
Value (Byte 1) EC
h
Value (Byte 0) 78
h
Checksum DC
h
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com