User Manual

TMCM-1276 CANopen
®
Firmware Manual Firmware Version V3.22 | Document Revision V1.00 2018-JUN-28
91 / 114
8.2 Detailed Object Specications
8.2.1 Object 6040
h
: Control Word
This object indicates the received command controlling the power drive system nite state automaton
(PDS FSA). The CiA-402 state machine can be controlled using this object. Please refer to gure 8 for
detailed information.
Structure of the Control Word
15 11 10 9 8 7 6 4 3 2 1 0
nu r oms h fr oms eo qs ev so
MSB LSB
Legend: nu=not used; r=reserved; oms=operation mode specic; h=halt; fr=fault reset; eo=enable opera-
tion; qs=quick stop; ev=enable voltage; so=switch on.
Table 273: Structure of the Control Word in hm Mode
Operation Mode specic Bits in hm Mode
Bit Name Denition
4 Homing operation start 1: start homing; 0: stop homing
8 Halt Not supported.
Table 274: Operation Mode specic Bits in hm Mode
Command Coding
Command Bits of Control Word Transitions
Bit 7 Bit 3 Bit 2 Bit 1 Bit 0
Shutdown 0 x 1 1 0 2,6,8
Switch on 0 0 1 1 1 3
Switch on & enable operation 0 1 1 1 1 3, 4
Disable voltage 0 x x 0 x 7,9,10,12
Quick stop 0 x 0 1 x 7,10,11
Disable operation 0 0 1 1 1 5
Enable operation 0 1 1 1 1 4, 16
Fault reset 0-to-1 x x x x 15
Table 275: Command Coding
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.