User Manual

TMCM-1276 CANopen
®
Firmware Manual Firmware Version V3.22 | Document Revision V1.00 2018-JUN-28
79 / 114
Command Coding
Command Bits of Control Word Transitions
Bit 7 Bit 3 Bit 2 Bit 1 Bit 0
Shutdown 0 x 1 1 0 2,6,8
Switch on 0 0 1 1 1 3
Switch on & enable operation 0 1 1 1 1 3, 4
Disable voltage 0 x x 0 x 7,9,10,12
Quick stop 0 x 0 1 x 7,10,11
Disable operation 0 0 1 1 1 5
Enable operation 0 1 1 1 1 4, 16
Fault reset 0-to-1 x x x x 15
Table 244: Command Coding
Object Description
Index Name Object Type Data Type
6040
h
Controlword Variable UNSIGNED16
Table 245: Object Description (6040
h
in pv Mode)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw see CiA402-3 See command coding above.
Table 246: Entry Description (6040
h
in pv Mode)
7.1.2 Object 6041
h
: Status Word
This object provides the status of the PDS FSA. It reects the status of the CiA-402 state machine. Please
refer to gure 8 for detailed information. The object is structured as dened below.
For more information about the coding please refer to the CANopen Drives and motion control device
prole, part 2.
Structure of the Status Word
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
dir mot oms ila tr rm ms w sod qs ve f oe so rtso
MSB LSB
Legend: nu=not used; r=reserved; oms=operation mode specic; h=halt; fr=fault reset; oe=operation
enable; qs=quick stop; ve=voltage enable; so=switch on.
Table 247: Structure of the Status Word in pv Mode
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com