User Manual
TMCM-1276 CANopen
®
Firmware Manual • Firmware Version V3.22 | Document Revision V1.00 • 2018-JUN-28
52 / 114
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 ro no -2147483648. . . 2147483647 0
Table 139: Entry Description (2100
h
)
4.2.45 Object 2101
h
: Actual Load Value
This object shows the home offset. The value is given in microsteps.
Object Description
Index Name Object Type Data Type
2101
h
Home Offset Display Variable UNSIGNED16
Table 140: Object Description (2101
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 ro no 0. . . 1023 0
Table 141: Entry Description (2101
h
)
4.2.46 Object 2102
h
: Driver Error Flags
This object shows the error flags of the motor driver IC.
Error Flags
Bit Name Meaning
7 OT Overtemperature
6 OTPW Temperature pre-warning
5 UV Undervoltage
4 OCHS Overcurrent high side
3 OLB Open load on bridge B
2 OLA Open load on bridge A
1 OCB Overcurrent on bridge B
0 OCA Overcurrent on bridge A
Table 142: Driver Error Flags (2102
h
)
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com