User Manual
TMCM-1276 CANopen
®
Firmware Manual • Firmware Version V3.22 | Document Revision V1.00 • 2018-JUN-28
51 / 114
Object Description
Index Name Object Type Data Type
20B8
h
High Speed Chopper Mode Variable UNSIGNED8
Table 134: Object Description (20B8
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0/1 0
Table 135: Entry Description (20B8
h
)
4.2.43 Object 20B9
h
: Power Down Ramp
The value set by this object controls the number of clock cycles for motor power down after a motion as
soon as the motor has stopped and the setting time (set by object 2089
h
, please see section 4.2.15) has
expired. The smooth transition avoids a motor jerk upon power down.
• 0=instant power down.
• 15=longest possible power down ramp.
Object Description
Index Name Object Type Data Type
20B9
h
Power Down Ramp Variable UNSIGNED8
Table 136: Object Description (20B9
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 15 7
Table 137: Entry Description (20B9
h
)
4.2.44 Object 2100
h
: Home Offset Display
This object shows the home offset. The value is given in microsteps.
Object Description
Index Name Object Type Data Type
2100
h
Home Offset Display Variable SIGNED32
Table 138: Object Description (2100
h
)
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com