User Manual

TMCM-1276 CANopen
®
Firmware Manual Firmware Version V3.22 | Document Revision V1.00 2018-JUN-28
43 / 114
Object Description
Index Name Object Type Data Type
2098
h
Smart Energy Current Minimum Variable UNSIGNED8
Table 98: Object Description (2098
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0/1 0
Table 99: Entry Description (2098
h
)
4.2.25 Object 2099
h
: Smart Energy Current Down Step
This object provides the setting of the number of stallGuard2 readings above the upper threshold necessary
for each current decrement of the motor current.
Possible values are:
0 32 measurements slowest decrement
1 8 measurements
2 2 measurements
3 1 measurements fastest decrement
Object Description
Index Name Object Type Data Type
2099
h
Smart Energy Current Down Step Variable UNSIGNED8
Table 100: Object Description (2099
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 3 0
Table 101: Entry Description (2099
h
)
4.2.26 Object 209A
h
: Smart Energy Hysteresis
This object sets the distance between the lower and the upper threshold for stallGuard2 reading. Above
the upper threshold the motor current becomes decreased.
Hysteresis: (smartEnergy hysteresis value + 1) 32
Upper stallGuard threshold: (smartEnergy hysteresis start + smartEnergy hysteresis + 1) 32
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.