There are several parameter groups:
Sub-index 0
h
: contains the largest sub-index that is supported.
Sub-index 1
h
: saves all parameters.
Sub-index 2
h
: saves communication parameters 100C
h
, 100D
h
, 1015
h
, 1017
h
, and 1029
h
.
Sub-index 3
h
: saves device prole parameters.
Sub-index 4
h
: saves motor 0 parameters.
Note
In order to avoid storage of parameters by mistake, storage is only executed
when a specic signature is written to the appropriate sub-Index. This signature
is "save" (65766173
h
, see also table 23).
Save Signature
e v a s
65
h
76
h
61
h
73
h
Table 23: Save Signature
On reception of the correct signature in the appropriate sub-index the device stores the parameter and
then conrms the SDO transmission (initiate download response). If the storing failed, the device responds
with an abort SDO transfer (abort code: 06060000
h
). If a wrong signature is written, the device refuses to
store and responds with abort SDO transfer (abort code: 0800002x
h
).
On read access, each sub-index provides information if it is possible to store the parameter group. It reads
1 if yes and 0 if no.
Object Description
Index Name Object Type Data Type
1010
h
Store Parameters Array UNSIGNED32
Table 24: Object Description (1010
h
)
Entry Description
Sub-index Description Access PDO Mapping Value Range Default Value
01h Save all parameters rw no UNSIGNED32
02h Save communication parameters rw no UNSIGNED32
03h Save device prole parameters rw no UNSIGNED32
04h Save motor axis 0 parameters rw no UNSIGNED32
Table 25: Entry Description (1010
h
)