User Manual
TMCM-1270 Hardware Manual • Hardware Version V1.00 | Document Revision V1.20 • 2017-SEP-27
13 / 21
NOTICE
Do not connect or disconnect motor during operation!
Motor cable and mo-
tor inductivity might lead to voltage spikes when the motor is connected / discon-
nected while energized. These voltage spikes might exceed voltage limits of the
driver MOSFETs and might permanently damage them. Therefore, always switch
off or disconnect power supply before connecting or disconnecting the motor.
4.4 LEDs
The TMCM-1270 includes two LEDs: one green status LED and one red error LED. See figure 10 for LED
location.
Green LED
Red LED
Figure 10: TMCM-1270 LED colors and loacation
Depending on the firmware option (TMCL or CANopen), these LEDs have different functionality. Main
states for TMCL:
State green LED State red LED Description TMCL Firmware
Flashing off Firmware running (normal operation mode)
Permanent on Permanent on Bootloader mode, firmware update supported
Table 7: LED functionality description
For CANopen firmware LED functionality has been implemented based on CANopen standard.
©2017 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.