User Manual

TMCM-1270 TMCL
Firmware Manual Firmware Version V1.00 | Document Revision V1.0 2017-Mar-02
55 / 87
Instruction Description Type Value
135 get application status Return information
about the current
status, depending on
the type eld.
0 - return mode,
wait ag, memory
pointer
1 - return mode,
wait ag, program
counter
2 - return
accumulator
3 - return X
register
0 (dont care)
136 get rmware version Return rmware
version in string
format (special reply)
or binary format).
0 - string format
1 - binary format
0 (dont care)
137 restore factory settings Reset all settings in
the EEPROM to their
factory defaults.
This command does
not send a reply.
0 (dont care) set to 1234
Table 10: TMCL Control Commands
Especially the commands 128, 129, 131 and 136 are interesting for use in custom host applications. The
other control commands are to be used mainly by the TMCL-IDE.
©2017 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com