User Manual
TMCM-1210 TMCL
™
Firmware Manual • Firmware Version V1.11 | Document Revision V1.00 • 2017-JUN-19
35 / 96
Reply (Status=no error, Value=302)
Field Value
Host address 02
h
Target address 01
h
Status 64
h
Instruction 0F
h
Value (Byte 3) 00
h
Value (Byte 2) 00
h
Value (Byte 1) 01
h
Value (Byte 0) 2E
h
Checksum A5
h
Bank 0 – Digital Inputs
The digital input states can be accessed in bank 0.
Digital I nputs in Bank 0
Port Command Range
IN0 GIO 0, 0 0/1
Special case: GIO 255, 0 reads all general purpose inputs simulataneously and puts the result into the the
accumulator register. The result is a bit vector where each bit represents one input.