User Manual

TMCM-1070 TMCL
Firmware Manual Firmware Version V1.01 | Document Revision V1.1 2017-Mar-02
29 / 38
6.3 Reset to Factory Defaults
The TMCM-1070 provides a functionality to restore all parameters to their factory default values. When
the module is still o, connect the SWIO and SWCLK programming pins, located on the bottom of the mod-
ule, with each other. Then, turn the power on. The module will write now the default values to the EEPROM.
At this point, the diode should be blinking fast and cant answer any commands. Disconnect the two
programming pins and reset the module. If the diode frequency didnt change, the factory reset was not
successful.
6.4 Conguration with the TMCL-IDE Plugin
When using a PC and the TMCL-IDE, the TMCM-1070 can be easily congured with the Module Settings
plugin. This tool provides a direct graphic interface to the most important parameters of the module.
Figure 3 shows the rst tab of the tool, which is called Current. In this tab, the tool shows the current value
of the axis parameters 6, 7 and 8, related to the motor current, and allows the user to modify them. The
button on the bottom left corner sends a STAP for each of the parameters related to the current tab. In
this case, parameters 6, 7 and 8 would be stored in the EEPROM of the module.
The next tab, Microstep, works in a similar way and aects parameters 140, 141 and 142. When this tab is
active, these three parameters would be stored in EEPROM after clicking on Store Current Tab.
Figure 3: TMCL-IDE Plugin: Tab Current
The StealthChop tab is shown on Figure 4. Parameter 137 Chopconf contains the value to be written in
the register with the same name. The graphical interface allows the user to change individual elds of the
register without having to look up the eld bits in the reference manual of TMC5130.
The last eld Upper Velocity Limit relates to parameter 136. When rotating at the desired speed limit,
click on Read from TSTEP to ll it automatically with the value from register 135 converted to step per
second. The velocity value is approximated because of the possible inaccuracy of the TMC5130 internal
clock.
Store Current Tab button stores in this case parameters 136 and 137 in the EEPROM.
SpreadCycle tab works like StealthChop tab for axis parameter 139 and the elds of its related register.
©2017 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany