User Manual
TMCM-1070 TMCL
™
Firmware Manual • Firmware Version V1.01 | Document Revision V1.1 • 2017-Mar-02
26 / 38
5 Global Parameters
The following sections describe all global parameters that can be used with the SGP, GGP, AGP, STGP and
RSGP commands. Global parameters are grouped into banks:
• Bank 0: Global configuration of the module.
5.1 Bank 0
Parameters with numbers from 64 on configure stuff like the serial address of the module RS485 baud
rate or the CAN bit rate. Change these parameters to meet your needs. The best and easiest way to do
this is to use the appropriate functions of the TMCL-IDE. The parameters with numbers between 64 and
128 are automatically stored in the EEPROM.
Note
•
An SGP command on such a parameter will always store it permanently and
no extra STGP command is needed.
•
Take care when changing these parameters, and use the appropriate func-
tions of the TMCL-IDE to do it in an interactive way!
Meaning of the Letters in the Access Column
Access type Command Description
R GGP Parameter readable
W SGP, AGP Parameter writable
E STGP, RSGP Parameter can be stored in the EEPROM
A SGP Automatically stored in the EEPROM
Table 9: Meaning of the Letters in the Access Column
All Global Parameters of the TMCM-1070 Module in Bank 0
Number Global Parameter Description Range [Units] Default Access
65 Serial baud rate RS485/RS232 baud rate
0 - 9600 baud
1 - 14400 baud
2 - 19200 baud
3 - 28800 baud (not supported by
TMCL-IDE)
4 - 38400 baud
5 - 57600 baud
6 - 76800 baud
7 - 115200 baud
0 . . . 7 0 RWA
66 Serial address
The module (target) address for
RS485, RS232, and virtual COM port.
1 . . . 255 1 RWA
76 Serial host
address
Host address used in the reply tele-
grams sent back via RS485/RS232.
1 . . . 255 2 RWA