Reply (Status=no error, Value=302)
Field Value
Host address 02
h
Target address 01
h
Status 64
h
Instruction 0F
h
Value (Byte 3) 00
h
Value (Byte 2) 00
h
Value (Byte 1) 01
h
Value (Byte 0) 2E
h
Checksum A5
h
Bank 0 Digital Inputs
The digital input states can be accessed in bank 0.
Digital Inputs in Bank 0
Port Description Command Range
0 - CHOP Chopper selection GIO 0, 0 0/1
1 - Enable Enable module GIO 1, 0 0/1