• Automatic motor stop on deviation error is also usable. This can be set using axis parameter
212 (maximum deviation). This function is turned off when the maximum deviation is set to 0.
5.6 Additional In- and Outputs
The In- and Outputs are not protected, only IN8 and IN9 are optically isolated.
Name Pin
Related
[TMCL]
command
Characteristics
IN1_A/D 0 GIO 0 Analog user controlled input #0. No internal resistors. 0…5V
IN2_A/D 26 GIO 1 Analog user controlled input #1. No internal resistors. 0…5V
IN3_A/D 13 GIO 2 Analog user controlled input #2. No internal resistors. 0…5V
IN4 21 GIO 3 Digital user controlled input #3. No internal resistors. TTL levels
IN5 32 GIO 4 Digital user controlled input #4. No internal resistors. TTL levels
IN6 25 GIO 5 Digital user controlled input #5. No internal resistors. TTL levels
IN7 30 GIO 6 Digital user controlled input #6. No internal resistors. TTL levels
IN8 11 GIO 7 Digital user controlled input #7. Optically isolated, active low
IN9 23 GIO 8 Digital user controlled input #8. Optically isolated, active low
OUT1 17 SIO 0, 2 Digital user controlled output #0. No internal resistors. TTL levels
OUT2 9 SIO 1, 2 Digital user controlled output #1. No internal resistors. TTL levels
OUT3 22 SIO 2, 2 Digital user controlled output #2. No internal resistors. TTL levels
Table 5.3: Additional In- and Outputs
5.7 Reference Switches
Two digital reference / stop switch inputs are provided (REF L= stop left and REF R = stop right). They
are used as an absolute position reference for homing and to set a hardware limit for the motion
range. Also a step loss of the system can be detected, e.g. due to overloading or manual interaction,
by using a travel-switch. The inputs are optically isolated, active low and use TTL levels.
5.7.1 Left and right limit switches
The TMCM-301 can be configured so that a motor has a left and a right limit switch (Figure 5.2). The
motor stops when the traveler has reached one of the limit switches.
left stop
switch
right stop
switch
REF_L_x REF_R_x
motor
traveler
Figure 5.2: Left and right limit switches
5.7.2 Triple Switch Configuration
It is possible to program a tolerance range around the reference switch position. This is useful for a
triple switch configuration, as outlined in Figure 5.3. In that configuration two switches are used as
automatic stop switches, and one additional switch is used as the reference switch between the left