1.2.3 MST (Motor Stop)
The motor is instructed to stop with the MST function. The axis parameter target
velocity is set to zero.
Related commands: ROL, ROR, SAP, GAP
Mnemonic: MST 0
NOTE:
An example for MST is provided Table 14.
MST Request in Direct Mode
COMMAND
TYPE
MOT/BANK
VALUE
3
don’t care
0
don’t care
Table 12: MST (Motor Stop) Request in Direct Mode
MST Reply in Direct Mode
STATUS
COMMAND
VALUE
100 – OK
3
don’t care
Table 13: MST (Motor Stop) Reply in Direct Mode
MST Example:
Stop Motor at Mnemonic: MST 0
Byte Index
0
1
2
3
4
5
6
7
Function
Target-
address
Instruction
Number
Type
Motor/
Bank
Operand
Byte3
Operand
Byte2
Operand
Byte1
Operand
Byte0
Value (hex)
$01
$03
$00
$00
$00
$00
$00
$00
Table 14: MST Example: Stop Motor at Mnemonic: MST 0