11.2 How to move a Motor in cst Mode
Here is a little example that shows how to get a motor running in cst mode. In this little example we
assume that the module has been reset (and then switched to start) by NMT commands before.
• Select cst mode by writing 10 to object 6060
h
(Modes_of_Operation).
• Write 6 to object 6040
h
(Controlword) to switch to READY_TO_SWITCH_ON state.
• Write 7 to object 6040
h
to switch to SWITCHED_ON state.
• Write the desired torque (e.g. 1000) to object 6071
h
(Target_Torque).
• Write 15 to object 6040
h
to switch to OPERATION_ENABLED state to start the motor.
• To stop the motor, write 0 to object 6071
h
.