Datasheet
TMC8462 Datasheet • Document Revision V1.5 • 2019-June-21
88 / 204
6.4.13.7 Type (+0xB)
Bit Description ECAT PDI Reset Value
0 0: Ignore mapping for read accesses
1: Use mapping for read accesses
r/w r/-
1 0: Ignore mapping for write accesses
1: Use mapping for write accesses
r/w r/-
7:2 Reserved, write 0 r/- r/-
Table 78: Register 0x06yB (FMMU Type)
6.4.13.8 Activate (+0xC)
Bit Description ECAT PDI Reset Value
0 0: FMMU deactivated
1: FMMU activated. FMMU checks logical ad-
dressed blocks to be mapped according to
mapping configured
r/w r/-
7:1 Reserved, write 0 r/- r/-
Table 79: Register 0x06yC (FMMU Activate)
6.4.13.9 Reserved (+0xD:0xF)
Bit Description ECAT PDI Reset Value
23:0 Reserved, write 0 r/- r/-
Table 80: Register 0x06yD:0x06yF (Reserved)
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com