6.4.8 Error Counters
Errors are only counted if the corresponding port is enabled.
6.4.8.1 RX Error Counter[3:0] (0x0300:0x0307)
Bit Description ECAT PDI Reset Value
7:0
Invalid frame counter of Port y (counting is
stopped when 0xFF is reached).
r/
w(clr)
r/-
15:8
RX Error counter of Port y (counting is stopped
when
0xFF
is reached). This is coupled directly
to RX ERR of MII interface.
r/
w(clr)
r/-
Table 44: Register 0x0300:0x0307 (RX Err Cnt)
6.4.8.2 Forward RX Error Counter[3:0] (0x0308:0x030B)
Bit Description ECAT PDI Reset Value
7:0
Forwarded error counter of Port y (counting is
stopped when 0xFF is reached).
r/
w(clr)
r/-
Table 45: Register 0x0308:0x030B (FW RX Err Cnt)
Note
Error Counters
0x0300
-
0x030B
are cleared if one of the RX Error counters
0x0300
-
0x030B is written. Write value is ignored (write 0).
6.4.8.3 ECAT Processing Unit Error Counter (0x030C)
Bit Description ECAT PDI Reset Value
7:0
ECAT Processing Unit error counter (counting is
stopped when
0xFF
is reached). Counts errors
of frames passing the Processing Unit (e.g., FCS
is wrong or datagram structure is wrong).
r/
w(clr)
r/-
Table 46: Register 0x030C (Proc. Unit Err Cnt)
Note
Error Counter
0x030C
is cleared if error counter
0x030C
is written. Write value is
ignored (write 0).