Datasheet

TMC8462 Datasheet Document Revision V1.5 2019-June-21
131 / 204
7.3.5.10 Register 45 PWM_PULSE_B_PULSE_A
Bit Description ECAT PDI Range [Unit]
11:0
Programmable trigger pulse A value with re-
spect to the common PWM counter.
-/w -/w 0. . . +(2
12
) 1
15:12 unused -/w -/w
27:16
Programmable trigger pulse B value with re-
spect to the common PWM counter.
-/w -/w 0. . . +(2
12
) 1
31:28 unused -/w -/w
Table 170: MFC IO Register 45 PWM_PULSE_B_PULSE_A
7.3.5.11 Register 46 PWM_PULSE_LENGTH
Bit Description ECAT PDI Range [Unit]
7:0
Programmable pulse length for trigger pulse A,
B, PWM start, and PWM center.
-/w -/w 0. . . +(2
8
) 1
Table 171: MFC IO Register 46 PWM_PULSE_LENGTH