Datasheet
TMC8462 Datasheet • Document Revision V1.5 • 2019-June-21
129 / 204
7.3.5.2 Register 37 – PWM1
Bit Description ECAT PDI Range [Unit]
11:0 PWM duty cycle (on time) for PWM1 -/w -/w 0. . . +(2
12
) − 1
15:12 unused -/w -/w
Table 162: MFC IO Register 37 – PWM1
7.3.5.3 Register 38 – PWM2
Bit Description ECAT PDI Range [Unit]
11:0 PWM duty cycle (on time) for PWM2 -/w -/w 0. . . +(2
12
) − 1
15:12 unused -/w -/w
Table 163: MFC IO Register 38 – PWM2
7.3.5.4 Register 39 – PWM3
Bit Description ECAT PDI Range [Unit]
11:0 PWM duty cycle (on time) for PWM3 -/w -/w 0. . . +(2
12
) − 1
15:12 unused -/w -/w
Table 164: MFC IO Register 39 – PWM3
7.3.5.5 Register 40 – PWM4
Bit Description ECAT PDI Range [Unit]
11:0 PWM duty cycle (on time) for PWM4 -/w -/w 0. . . +(2
12
) − 1
15:12 unused -/w -/w
Table 165: MFC IO Register 40 – PWM4
7.3.5.6 Register 41 – PWM1_CNTRSHFT
Bit Description ECAT PDI Range [Unit]
11:0
Shift value for PWM1 to shift PWM1 high side
and low side signal edges with respect to the
aligned PWM counter.
-/w -/w 0. . . +(2
12
) − 1
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com