Datasheet

TMC6200 DATASHEET (Rev. 1.04 / 2019-AUG-08) 37
www.trinamic.com
Charge Pump
DC-Characteristics
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Charge pump output voltage
V
VCP
-V
VS
operating
V
12VOUT
-
2
V
12VOUT
-
1
V
Charge pump voltage threshold
for undervoltage detection
V
VCP
-V
VS
rising, using internal
5V regulator voltage
4.5
5.5
6.5
V
Charge pump frequency
f
CP
1/32
f
CLKOSC
Linear Regulator
DC-Characteristics
V
VS
= V
VSA
= 24.0V
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Output voltage
V
5VOUT
T
J
= 25°C
4.80
5.0
5.20
V
Deviation of output voltage over
the full temperature range
V
5VOUT(DEV)
drivers disabled
T
J
= full range
+/-5
+/-50
mV
Deviation of output voltage over
the supply voltage
V
5VOUT(DEV)
drivers disabled,
internal clock
T
A
= 25°C
V
VSA
= 10V to 30V
+/-20
mV /
10V
Output voltage
V
12VOUT
operating, internal
clock
T
J
= 25°C
10.8
11.5
12.2
V
Clock Oscillator and Input
Timing-Characteristics
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Clock oscillator frequency
(factory calibrated)
f
CLKOSC
t
J
=-50°C
23.4
MHz
f
CLKOSC
t
J
=50°C
23
24.0
25
MHz
f
CLKOSC
t
J
=150°C
24.2
MHz
External clock frequency
(operating)
f
CLK
40%..60% dutycycle
for typ. 50% for max.
4
10-13.4
16
MHz
External clock high / low level
time
t
CLKH
/
t
CLKL
CLK driven to
0.1 V
VIO
/ 0.9 V
VIO
10
ns
External clock timeout detection
in cycles of internal f
CLKOSC
t
CLKH1
CLK driven high
32
48
cycles
f