Datasheet

TMC4671 Datasheet IC Version V1.00 | Document Revision V1.03 2018-Sept-06
66 / 158
Address Registername Access
Mask Name Type
0x000000FF
h
ADC_I0_SELECT Choice
Min Max Default Unit
0 3 0
Select input for raw current ADC_I0_RAW.
0: ADCSD_I0_RAW (sigma delta ADC)
1: ADCSD_I1_RAW (sigma delta ADC)
2: ADC_I0_EXT (from register)
3: ADC_I1_EXT (from register)
Mask Name Type
0x0000FF00
h
ADC_I1_SELECT Choice
Min Max Default Unit
0 3 1
Select input for raw current ADC_I1_RAW.
0: ADCSD_I0_RAW (sigma delta ADC)
1: ADCSD_I1_RAW (sigma delta ADC)
2: ADC_I0_EXT (from register)
3: ADC_I1_EXT (from register)
Mask Name Type
0x03000000
h
ADC_I_UX_SELECT Choice
Min Max Default Unit
0 2 0
0: UX = ADC_I0 (default)
1: UX = ADC_I1
2: UX = ADC_I2
Mask Name Type
0x0C000000
h
ADC_I_V_SELECT Choice
Min Max Default Unit
0 2 1
0: V = ADC_I0
1: V = ADC_I1 (default)
2: V = ADC_I2
Mask Name Type
0x30000000
h
ADC_I_WY_SELECT Choice
Min Max Default Unit