Datasheet
TMC4671 Datasheet • IC Version V1.00 | Document Revision V1.03 • 2018-Sept-06
25 / 158
Figure 14:
Delta Sigma ADC Configurations dsADC_CONFIG (internal: ANALOG vs. external: MCLKO, MCLKI, MDAC)
dsADC_CONGIG Description NC_MCLKO_MCLKI_MDAC VIN_MDAT
ANALOG
integrated internal ADC mode,
VIN_MDAT is analog input VIN
MCLK not connected (NC) VIN (analog)
MCLKO
external dsModulator (e.g.
AD7403) with MCLK input
driven by MCLKO
MCLK output MDAT input
MCLKI
external dsModulator (e.g.
AD7400) with MCLK output
that drives MCLKI
MCLK input MDAT input
MDAC
external dsModulator (e.g.
LM339, LM319) realized by
external comparator CMP with
two R and one C
MDAC output (= MCLK out) MDAT input for CMP
Table 7: Delta Sigma ADC Configurations (figure 14), selected with dsADC_MCFG_A and dsADC_MCFG_B.
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com