In this example external start signal triggers are prioritized by making use of
START_DELAY
> 0 and simultaneously setting
immediate_start_in
to 1.
When
XACTUAL
equals
POSCOMP
the start timer is activated and the external
start signal in between is ignored.
The second start event is triggered by an external start signal. The
POSCOMP_REACHED
event is ignored.
The third start timer process is disrupted by the external START signal, which is
forced to be executed immediately due to the setting of:
immediate_start_in
= 1.
Parameter Settings Timing Example 3
Parameter
Setting
RAMPMODE
b’000
start_en
b’00010
trigger_events
b’1001
immediate_start_in
0 1
START_DELAY
>0
pol_start_signal
1
Table 35: Parameter Settings Timing Example 3
Figure 36: Ramp Timing Example 3
SPI
VMAX
= -1000
v(t)
1000
POSCOMP_REACHED
internal start signal
START
internal start timer
t
START_DELAY
trigger event
XACTUAL=POSCOMP
-1000
VMAX
=1000
START_DELAY
trigger event
VMAX
=250
VMAX
= -250
immediate_start_in
=1
ignored trigger event due
to ongoing start timer
trigger event
trigger event
XACTUAL=POSCOMP
ignored trigger event due
to ongoing start timer
Ramp Timing
Example 3
Process
Description