Datasheet

TMC4361A Datasheet | Document Revision 1.22 2017-JAN-12
71/230
© 2015 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany Terms of delivery and rights
to technical change reserved. Download newest version at: www.trinamic.com .
Read entire documentation; especially the Supplemental Directiveson page 224.
MAIN MANUAL
Per default, the trigger is closely followed by the internal start signal.
In order to delay the generation of the internal start signal, do the
following:
Action:
Set
START_DELAY
register 0x13 according to your specification.
Result:
When a start trigger is recognized, the internal start signal is generated after
START_DELAY
clock cycles.
Per default, an external trigger is also delayed for the internal start signal generation.
In order to immediately prompt an external start, trigger to an internally
generated start signal (regardless of a defined delay), do the following:
Action:
Set
immediate_start_in
= 1 (
START_CONF
register 0x02).
Result:
When an external start trigger is recognized, the internal start signal is generated
immediately, even if the internal start triggers have already initiated a timing process
with an active delay.
The START pin can be used either as input or as output pin. However, the active
voltage level polarity of the START pin can be selected with one configuration switch
in the
START_CONF
register 0x02.
Per default, the voltage level transition from high to low triggers a start signal (START
is an input), or START output indicates an active START event by switching from high
to low level.
In order to invert active START polarity, do as follows:
Action:
Set
pol_start_signal
= 1 (
START_CONF
register 0x02).
Result:
The START pin is high active. The voltage level transition from low to high triggers a
start signal (START is an input), or START output indicates an active START event by
switching from low to high level.
Per default, the active output voltage level of the START pin lasts one clock cycle.
In order to extend this time span, do the following:
Condition:
START pin is assigned as output:
trigger_events
(0) = 1.
Action:
Set
START_OUT_ADD
register 0x11 according to your specification.
Result:
The active voltage level lasts (
START_OUT_ADD
+ 1) clock cycles.
Delay Definition
between Trigger
and internally
generated Start
Signal
Prioritizing
External Input
START Pin
Polarity
Active START Pin
Output
Configuration