Datasheet

TMC4361A Datasheet | Document Revision 1.22 2017-JAN-12
61/230
© 2015 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany Terms of delivery and rights
to technical change reserved. Download newest version at: www.trinamic.com .
Read entire documentation; especially the Supplemental Directiveson page 224.
MAIN MANUAL
STOPL and STOPR inputs can also be used as HOME_REF inputs.
OPTION 1: STOPL IS THE HOME SWITCH
Action:
Set
stop_left_is_home
= 1 (
REFERENCE_CONF
register 0x01).
Result:
The stop event at STOPL only occurs when the home range is crossed after STOPL
becomes active. The home range is given by
X_HOME
and
HOME_SAFETY_MARGIN
.
OPTION 2: STOPR IS HOME SWITCH
Action:
Set
stop_right_is_home
= 1 (
REFERENCE_CONF
register 0x01).
Result:
The stop event at STOPR only occurs when the home region is crossed after STOPR
becomes active. The home region is given by
X_HOME
and
HOME_SAFETY_MARGIN
.
Homing with
STOPL or STOPR