Altering the Internal Motion Direction
Per default, a positive internal velocity
VACTUAL
results in a forward motion through internal
SinLUT. Consequently, if
VACTUAL
< 0, the SinLUT values are developed backwards.
In order to alter the default setting of the Internal Motion Direction, do as
follows:
Action:
Set
reverse_motor_dir
=1 (bit28 of
GENERAL_CONF
register 0x00).
Result:
A positive internal velocity for
VACTUAL
results in a backward motion through the
internal SinLUT.
How to change