Datasheet

TMC4361A Datasheet | Document Revision 1.22 2017-JAN-12
207/230
© 2015 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany Terms of delivery and rights
to technical change reserved. Download newest version at: www.trinamic.com .
Read entire documentation; especially the Supplemental Directiveson page 224.
MAIN MANUAL
Freeze Register
The freeze register can only be written once after an active reset and before motion starts. It
is always readable.
Reset and Clock Gating Register
FREEZE Register
R/W
Addr
Bit
Val
Description
RW
0x4E
23:0
DFREEZE (Default: 0x000000)
U
Freeze event deceleration value.
In case NFREEZE switches to low level, this parameter is used for an automatic
linear ramp stop.
Setting
DFREEZE
to 0 leads to an hard stop.
Value representation:
Frequency mode: not available
Direct mode: [∆v per clk cycle]
a[∆v per clk_cycle]=
DFREEZE
/ 2
37
DFREEZE
[pps
2
] =
DFREEZE
/ 2
37
• f
CLK
2
Set
DFREEZE
2
20
.
31:24
IFREEZE (Default: 0x00)
U
Scaling value in case NFREEZE is tied low.
In case
IFREEZE
=0, actual active scaling value is valid at FROZEN event.
Table 87: Freeze Register
Reset and Clock Gating Register
R/W
Addr
Bit
Val
Description
RW
0x4F
2:0
CLK_GATING_REG (Default: 0x0)
0
Clock gating is not activated.
7
Clock gating is activated.
31:8
RESET_REG (Default: 0x000000)
0
No reset is activated.
0x525354
Internal reset is activated.
Table 88: Reset and Clock Gating Register