Ramp Generator Registers
R/W
Addr
Bit
Val
Description
RW
0x2A
23:0
ASTART (Default: 0x000000)
U
S-shaped ramp motion profile: start acceleration value.
Trapezoidal ramp motion profile:
Acceleration value in case |
VACTUAL
| <
VBREAK
.
Acceleration value after switching from external to internal step control.
Value representation:
Frequency mode: [pulses per sec
2
]
22 digits and 2 decimal places: 250 mpps
2
≤
ASTART
≤ 4 Mpps
2
Direct mode: [∆v per clk cycle]
a[∆v per clk_cycle]=
ASTART
/ 2
37
ASTART
[pps
2
] =
ASTART
/ 2
37
• f
CLK
2
Consider maximum values, represented in section 6.7.5, page 50
31
Sign of
AACTUAL
after switching from external to internal step control.
0x2B
23:0
DFINAL (Default: 0x000000)
U
S-shaped ramp motion profile: Stop deceleration value, which is not used during
positioning mode.
Trapezoidal ramp motion profile:
Deceleration value in case |
VACTUAL
| <
VBREAK
.
Value representation:
Frequency mode: [pulses per sec
2
]
22 digits and 2 decimal places: 250 mpps
2
≤
DFINAL
≤ 4 Mpps
2
Direct mode: [∆v per clk cycle]
d[∆v per clk_cycle]=
DFINAL
/ 2
37
DFINAL
[pps
2
] =
DFINAL
/ 2
37
• f
CLK
2
Consider maximum values, represented in section 6.7.5, page 50
0x2C
23
DSTOP (Default: 0x000000)
U
Deceleration value for an automatic linear stop ramp to
VACTUAL
= 0.
DSTOP
is used with activated external stop switches (STOPL or STOPR) if
soft_stop_enable
is set to 1; or with activated virtual stop switches and
virt_stop_mode
is set to 2.
Value representation:
Frequency mode: [pulses per sec
2
]
22 digits and 2 decimal places: 250 mpps
2
≤
DSTOP
≤ 4 Mpps
2
Direct mode: [∆v per clk cycle]
d[∆v per clk_cycle]=
DSTOP
/ 2
37
DSTOP
[pps
2
] =
DSTOP
/ 2
37
• f
CLK
2
Consider maximum values, represented in section 6.7.5, page 50
Continued on next page!