Datasheet
TMC2300 DATASHEET (Rev. 1.02 / 2019-NOV-06) 31
www.trinamic.com
5.5.3 DRV_STATUS – Driver Status Flags
0X6F: DRV_STATUS – DRIVER STATUS FLAGS AND CURRENT LEVEL READ BACK
Bit
Name
Function
Comment
31
stst
standstill indicator
This flag indicates motor stand still in each operation
mode. This occurs 2^20 clocks after the last step pulse.
30
-
reserved
Ignore these bits
29
28
27
26
25
24
23
-
reserved
Ignore these bits
22
21
20
CS_
ACTUAL
actual motor current /
smart energy current
Actual current control scaling, for monitoring the
function of the automatic current scaling.
19
18
17
16
15
-
reserved
Ignore these bits
14
13
12
11
-
0
Ignore these bits
10
9
t150
150°C comparator
1: Temperature threshold is exceeded, driver is off
8
t120
120°C comparator
1: Temperature prewarning threshold is exceeded
7
olb
open load indicator
phase B
1: Open load detected on phase A or B.
Hint: This is just an informative flag. The driver takes no
action upon it. False detection may occur in fast motion
and standstill. Check during slow motion, only.
6
ola
open load indicator
phase A
5
s2vsb
low side short
indicator phase B
1: Short on low-side MOSFET detected on phase A or B.
The driver becomes disabled. The flags stay active, until
the driver is disabled by software (enabledrv=0) or by
the ENN input. Flags are separate for both chopper
modes.
4
s2vsa
low side short
indicator phase A
3
s2gb
short to ground
indicator phase B
1: Short to GND detected on phase A or B. The driver
becomes disabled. The flags stay active, until the driver
is disabled by software (enabledrv=0) or by the ENN
input.
2
s2ga
short to ground
indicator phase A
1
ot
overtemperature flag
1: The overtemperature limit has been reached. Drivers
become disabled until otpw is also cleared due to
cooling down of the IC.
The overtemperature flag is common for both bridges.
0
otpw
overtemperature pre-
warning flag
1: The overtemperature pre-warning threshold is
exceeded.
The overtemperature pre-warning flag is common for
both bridges.