5.3.2 Transition Irun to Ihold
At the end of a motor motion the actual coil currents Irun are maintained in the coils at their actual DC
level for a quarter of an electrical period (two half steps) at minimum velocity. Afterwards the currents
are then set to their hold values Ihold. The figure below illustrates the mechanism:
t
i
I = I
run
I = I
hold
Figure 12: Transition Irun to Ihold
Both currents Irun and Ihold are parameterizeable using the command SetMotorParam. 16 values are
available for Irun current and 16 values for Ihold current. The table below shows the corresponding
current values.
Irun / Ihold setting
(hexadecimal)
Peak Current
[mA]
0x0 59
0x1 71
0x2 84
0x3 100
0x4 119
0x5 141
0x6 168
0x7 200
0x8 238
0x9 283
0xA 336
0xB 400
0xC 476
0xD 566
0xE 673
0xF 800
Table 12: Irun / Ihold Settings